Power Supplies

AC/DC adapters from 5 W to 800 W, built to your spec and approved for your market. Six form factors, one supplier.

DoE Level VI

Energy efficiency level 6, with no-load power of 0.1 W or less.

Low noise and ripple

100 mVp-p maximum on every output.

FCC Part 15B

Conducted and radiated emissions to FCC Part 15B and EN 55032.

2-year warranty

Two years on every unit, backed by a 20,000 hour MTBF.

Specifications

Platform data for the wall-mount adapters, 5 to 72 W. Desktop, waterproof and open frame units are quoted against the same protections and standards at their own ratings.

General

Product typeVertical or horizontal wall mount
Input voltage100 to 240 V AC, 50/60 Hz, 0.5 A
Output voltage3 to 48 V DC
Output current10 A max
AC plugNorth America, Europe, UK, Australia, Japan, Korea, China
DC wireRound, flat, nylon braid or custom
DC plugStripped and tinned, 5.5 x 2.1, 5.5 x 2.5, 4.0 x 1.7, 3.5 x 1.35, 6.3 x 3.0, USB-C, waterproof plugs, Molex or custom

Input

Rated input voltage100 to 240 V AC
Input voltage range90 to 264 V AC
Rated frequency50/60 Hz
Frequency range47 to 63 Hz
Maximum AC current0.5 A
Leakage current0.1 mA at 240 V AC
Inrush current30 A at 115 V AC, 60 A at 230 V AC
No-load power0.1 W max at 115 and 230 V AC

Output

Nominal output voltage3 to 48 V DC
Output current10 A max
Output power72 W max
Ripple and noise100 mVp-p max

Protections

Over voltageYes
Over currentBelow 170% of rated load, hiccup mode, auto-recovery
Over temperatureAuto-recovery
Short circuitHiccup mode, auto-recovery when the fault clears
Shock protectionClass I with PE connection, Class II models available

Reliability and environment

MTBFOver 20,000 hours
Operating temperature0 to 40 °C
Storage temperature-20 to 80 °C
Humidity10 to 90% RH, non-condensing
Altitude0 to 2,000 m

Insulation

Insulation resistance30 MΩ min at 500 V DC
Hi-pot3,750 V AC, 50 Hz, 60 s, 10 mA max

Standards

Safety standards by market, with the EMC and environmental standards every unit is tested to.

Safety

IT and AV equipmentUL/ETL 62368-1, EN 62368-1, BS EN 62368-1, AS/NZS 62368.1, K 62368, J 62368, GB 4943
Class 2 transformersUL/ETL 1310, EN 61558, BS EN 61558, AS/NZS 61558, J 61558, GB 4706
Household appliancesUL/ETL 60335, EN 60335, BS EN 60335, AS/NZS 60335, J 60335
MedicalUL/ETL 60601, EN 60601, BS EN 60601, AS/NZS 60601, J 60601

EMI

Conducted emissionEN 55032:2015+A11:2020, FCC Part 15B
Radiated emissionBS EN 55032:2015+A11:2020
FlickerEN 61000-3-3:2013+A1:2019

EMS

Electrostatic dischargeEN 61000-4-2, 8 kV air, 4 kV contact
RF fieldEN IEC 61000-4-3:2020
Fast transientsEN 61000-4-4:2012
SurgeEN 61000-4-5:2014+A1:2017

Environmental

RoHSEU Directive 2011/65/EU
REACHEC 1907/2006
WEEEEU Directive 2012/19/EU

Have a unique power or connectivity challenge?

Our engineers take OEM and ODM projects from your spec to a certified, shelf-ready product. Private-label branding, custom connectors and global certification included.