Power Supplies
AC/DC adapters from 5 W to 800 W, built to your spec and approved for your market. Six form factors, one supplier.
Energy efficiency level 6, with no-load power of 0.1 W or less.
100 mVp-p maximum on every output.
Conducted and radiated emissions to FCC Part 15B and EN 55032.
Two years on every unit, backed by a 20,000 hour MTBF.
Specifications
Platform data for the wall-mount adapters, 5 to 72 W. Desktop, waterproof and open frame units are quoted against the same protections and standards at their own ratings.
General
| Product type | Vertical or horizontal wall mount |
|---|---|
| Input voltage | 100 to 240 V AC, 50/60 Hz, 0.5 A |
| Output voltage | 3 to 48 V DC |
| Output current | 10 A max |
| AC plug | North America, Europe, UK, Australia, Japan, Korea, China |
| DC wire | Round, flat, nylon braid or custom |
| DC plug | Stripped and tinned, 5.5 x 2.1, 5.5 x 2.5, 4.0 x 1.7, 3.5 x 1.35, 6.3 x 3.0, USB-C, waterproof plugs, Molex or custom |
Input
| Rated input voltage | 100 to 240 V AC |
|---|---|
| Input voltage range | 90 to 264 V AC |
| Rated frequency | 50/60 Hz |
| Frequency range | 47 to 63 Hz |
| Maximum AC current | 0.5 A |
| Leakage current | 0.1 mA at 240 V AC |
| Inrush current | 30 A at 115 V AC, 60 A at 230 V AC |
| No-load power | 0.1 W max at 115 and 230 V AC |
Output
| Nominal output voltage | 3 to 48 V DC |
|---|---|
| Output current | 10 A max |
| Output power | 72 W max |
| Ripple and noise | 100 mVp-p max |
Protections
| Over voltage | Yes |
|---|---|
| Over current | Below 170% of rated load, hiccup mode, auto-recovery |
| Over temperature | Auto-recovery |
| Short circuit | Hiccup mode, auto-recovery when the fault clears |
| Shock protection | Class I with PE connection, Class II models available |
Reliability and environment
| MTBF | Over 20,000 hours |
|---|---|
| Operating temperature | 0 to 40 °C |
| Storage temperature | -20 to 80 °C |
| Humidity | 10 to 90% RH, non-condensing |
| Altitude | 0 to 2,000 m |
Insulation
| Insulation resistance | 30 MΩ min at 500 V DC |
|---|---|
| Hi-pot | 3,750 V AC, 50 Hz, 60 s, 10 mA max |
Standards
Safety standards by market, with the EMC and environmental standards every unit is tested to.
Safety
| IT and AV equipment | UL/ETL 62368-1, EN 62368-1, BS EN 62368-1, AS/NZS 62368.1, K 62368, J 62368, GB 4943 |
|---|---|
| Class 2 transformers | UL/ETL 1310, EN 61558, BS EN 61558, AS/NZS 61558, J 61558, GB 4706 |
| Household appliances | UL/ETL 60335, EN 60335, BS EN 60335, AS/NZS 60335, J 60335 |
| Medical | UL/ETL 60601, EN 60601, BS EN 60601, AS/NZS 60601, J 60601 |
EMI
| Conducted emission | EN 55032:2015+A11:2020, FCC Part 15B |
|---|---|
| Radiated emission | BS EN 55032:2015+A11:2020 |
| Flicker | EN 61000-3-3:2013+A1:2019 |
EMS
| Electrostatic discharge | EN 61000-4-2, 8 kV air, 4 kV contact |
|---|---|
| RF field | EN IEC 61000-4-3:2020 |
| Fast transients | EN 61000-4-4:2012 |
| Surge | EN 61000-4-5:2014+A1:2017 |
Environmental
| RoHS | EU Directive 2011/65/EU |
|---|---|
| REACH | EC 1907/2006 |
| WEEE | EU Directive 2012/19/EU |
Have a unique power or connectivity challenge?
Our engineers take OEM and ODM projects from your spec to a certified, shelf-ready product. Private-label branding, custom connectors and global certification included.